See detector placement and mounting sections of the beam detector manual for further details. Ec50r100r reflective beam detector data sheet k850010560 the ec50r100r comprises a transmitter and receiver in a single enclosure and is usually installed between 19 inches and 24 inches below the ceiling. Smoke detector location correct smoke detector location and spacing is critical in a properly installed and operating fire alarm system. Complete the installation of the transmitterreceiver unit using the instruc tions included with the beam detector. If it is necessary to pass though glass, the angle between the.
The relatively broad angle of the ir beam eases adjustment and guarantees reliable longterm stability. Engineers may provide assistance to achieve a satisfactory beam installation during technical support, the customer will remain responsible for installing. Product guide k853000010 kidde conventional systems. For ranges between 50m and 100m, use a 100m detector with 4 reflectors. D usually, the detector and the reflector are installed at the same height and oriented towards each other. The system is designed to be mounted so that the beam will project between 0. Hochiki spbet beam detector user manual 230294iss2feb2001 11 2. Monitor the voltage and turn on all heating and cooling devices in the area. The detector must be used together with a reflector. For installations complying with ul268nfpa72, the maximum. The fire beam brochure contains detailed information on the range of fire beam products. Smoke alarm fireray 50rv install manual 27 pages smoke alarm fireray 3000 user manual. The 50r100r optical beam smoke detectors monitor long term degradation of beam signal strength caused by the build.
Fireray 50100r installation video ffe ltd manufacturer of fireray and talentum. The infrared beam path must be kept clear of obstructions at all times. This detector offers cost effective protection of large, open area spaces with high ceilings. Detector placement this section of the manual discusses the placement of projected beam detectors. Beam1224, beam1224s singleended reflected type projected. Detector installation must comply with local regulations.
Ec 50r 100r reflective beam detector data sheet k850010560 the ec 50r 100r comprises a transmitter and receiver in a single enclosure and is usually installed between 19 inches and 24 inches below the ceiling. The installation of the fireray infrared optical beam smoke detector should be undertaken in. Installation sheet osid smoke detection system detach mounting bracket and front cover. Each d296 or d297 beam smoke detector has a separate transmitter and receiver. Builtin microprocessor enables intelligent judgment of fire alarm and fault. This manual uses the following warning indications for correct use of the product, harm to you or other people and damage to your assets, which are described below. Manual fire and fault tests after installation or cleaning, it is recommended that a manual fire and fault test is performed. The ec 50r 100r comprises a transmitter and receiver in a single enclsure and is usually installed between 19 inches and 24 inches below the ceiling. To select between four different beam frequencies, adjust the beam channel switch of the transmitter side and receiver side. Installation and maintenance instructions fsb200, fsb200s singleended reflected type projected beam smoke detector 12 clintonville rd. Intelligent beam smoke detectors beam200beam200s mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. Receiver installation procedure ribbon cable installation to beam detector.
The projected beam type smoke detector shall be a 4wire 1224 vdc device to be used with a separately supplied 4wire control panel. Its a great introduction to the fire beam all inside one pdf document. Cover the reflector slowly so that it takes longer than 5 seconds to. Edwards signaling ec50r 100r reflective beam smoke. I9105r intelligent reflective beam detector installation and operation manual the intelligent solution page 1 i general i9105r intelligent reflective beam detector hereinafter called the detector is an addressable reflective infrared beam smoke detector that can be connected with fire. Detector and reflector from the ceiling must be 10% of the distance between floor and ceiling.
Make sure that the following items are included in the package prior to installation. This manual has been prepared to help in the use and installation of the manning ecf9 nh 3 electrochemicalammonia sensor. The relatively broad angle of the ir beam eases adjustment and guarantees reliable. Jul 16, 2015 watch this video to understand the steps needed to install and align the 50100r reflective beam smoke detector. The fault relay will reset within 5 seconds of the condition being rectified. The detector shall operate between a range of 15 ft. System sensor beam detector is a fourwire conventional reflected beam smoke detector, which is uniquely suited for protecting open areas with high ceilings, where other methods of smoke detection are difficult to install and maintain.
System sensor beam detector, beam detector honeywell. Thread the 10 way ribbon cable through the back of the beam detector, so that the connector. In addition, each system controller houses two pairs of fire and fault relays, one per detector. Generalinformation 30cm 30cm transmitter receiver power supplyunit controller 5120m. Figure a infrared transmission as the beam is obscured by smoke, the receiver senses a decrease in. After reading, store this manual carefully in an easily accessible place for reference. Mount the detector on a stable mounting surface such as brick, concrete, a sturdy loadbearing wall, support column, structural beam, or other surface that is not expected to experience vibration or movement over time. Test and acceptance of the system shall be carried out by using the ululc approved internal electronic obscuration fire. View and download bosch fireray 50rv installation instructions manual online. It explains how it works, the features you get as standard, as well as information about our kits and accessories. The fsb200s is a singleended beam smoke detector with integral sensitivity test for use with onyx series panels. The fsb200 is a singleended beam smoke detector for use with onyx series panels.
Bosch fireray 50rv installation instructions manual pdf download. Endto end optical beam smoke detector user guide en. This manual is available online at general description system sensor model beam1224beam1224s is a long range projected beam smoke detector designed to provide open area protection. Reflected beam smoke detectors are designed for spacious rooms, open areas, and high ceilings. Nov 20, 2016 the fireray 50r100r series of reflective infrared optical beam smoke detectors are comprised of a single unit incorporating an infrared transmitter and receiver. Installation wire used for the beam detector shall be no smaller than 18 gauge 1. Alignment of fireray 100r reflective infrared optical beam. Test for beam distortion by monitoring the signal voltage. The fireray 3000 end to end infrared optical beam smoke detector obsd has been designed using the latest optical technology, incorporating modern industrial, electronic and software techniques. The model 6500rs includes an integral servo controlled calibrated test. I9105r intelligent reflective beam detector installation and. The model 6500r is a conventional long range projected beam smoke detector designed to provide open area protection.
All four holes must be used to provide secure mounting. Intelligent addressable conventional see whats possible now. Installation and maintenance instructions beam1224, beam1224s singleended reflected type projected beam smoke detector 3825 ohio avenue, st. Detector placement this section of the manual discusses the placement of pro. After setup, the detectors signal voltage must read 4 vdc. The receiver detects, then measures the beams intensity see figure a. Conventional devices fireray 50ru100ru ective beam. Installation option before installation of the beam detector it will be necessary to determine which type of wiring method will be used for connection between the beam detector and the control panel. Catalog number 2037 not to be used for installation purposes. Edwards signaling ec50r 100r reflective beam smoke detector.
Description quantity description quantity detector transmitter and receiver 1set clamping screw m4. This manual will convey the operating principles of the sensor, ensure proper installation, and. Add our ans system to any kidde installation and offer highend voice audio capabilities. I9105r intelligent reflective beam detector installation. Please follow the instructions in this step if you have chosen to secure the detector component to the mounting. This can be either on the vertical or horizontal axis. Alignment mode 4 reflective prisms for 1 reflective prism for the 100 metre detector the 50 metre detector ensure that there is a clear line of sight to the. The beam detector shall feature automatic gain control which will compensate for gradual signal deterioration from dirt accumulation on the lenses. Failure to comply may result in the system initiating a fire or fault signal detector installation must comply with local regulations. Smoke detector location correct smoke detector location and spacing is critical in. Photoelectric detector advanced standard detection. The transmitter emits an invisible infrared light beam that is reflected via a prism mounted directly opposite and with a clear line of sight. The detector can calibrate automatically, which ensures one person to complete adjustment in short time. Four alignment leds on the front of each unit indicate signal strength to ease alignment.
Failure to comply may result in the system initiating a fire or fault. Beammmk multimounting kit for use with reflective projected. Do not install the detector or reflector in environments where condensation or icing are likely to occur for ranges between 5m and 50m, use a 50m detector with 1 reflector. The installation of the fireray infrared optical beam smoke detector should be undertaken in accordance with recognized national or international standards and. Ec50r 100r reflective beam smoke detector edwards signaling. The detector base has four primary mounting holes, one in each corner of the base. Installation instructions linear smoke detector fireray 50100rv stpmfzab 610f. The ec50r100r comprises a transmitter and receiver in a single enclsure and is usually installed between 19 inches and 24 inches below the ceiling. The fireray 50r100r series of reflective infrared optical beam smoke detectors are comprised of a single unit incorporating an infrared transmitter and receiver.
Do not mount the beam detector on corrugated metal walls, sheet metal walls, external building sheathing. Position beam as high as possible, but with a minimum distance of 0. The transmitter transmits an invisible infrared beam of a specific frequency and intensity. This installation instruction provides the information and warning essential for installing this unit in a safe manner and for maintaining it in safe operating condition. I9105r intelligent reflective beam detector hereinafter called the detector is an addressable reflective infrared beam smoke detector that can be connected with fire alarm controller directly, transmitting state information through bus between the detector and controller. Digital flame proof reflective beam detector installation and operation manual the intelligent solution 2 3. Fireray 50r100r installation recommendations the installation of the ray infrared optical beam smoke detector should be undertaken in accordance with recognized national or international standards and codes of practice. The sensor beam frequency can be set at different levels onsite to avoid interference from other twin photobeam sensors nearby, which is useful during multiple sensor applications as shown below. The fireray 50r100r series of reflective infrared optical beam smoke detectors are comprised of a single unit incorporating an infrared transmitter and. The edwardssignalingec50r is a beam smoke detector that comprises a transmitter and receiver in a single enclosure and is usually installed between. Installation instructions d296 and d297 long range beam.
Please thoroughly read this manual and applicable sections of system sensors singleended reflected beam detector application guide bmag240. To detach the unit from the mounting bracket a, open the front cover and with a screwdriver push the lip backwards to then slide the unit up to detach from the mounting bracket. Though this information is based upon industry expertise, it is intended to. The signal is reflected by a prism and analysed for smoke presence. Limit to when a beam detector must be positioned in roof apex 0. The ul listed temperature range of the beam shall be 32f to 100f 0c to 37.
The remote test station with alarm led indicator, model rts451, is an accessory that mounts to a standard single gang box and can test and reset the beam detector from a remote location. Fire detection solutions, apollo fire detectors ltd. Ec100r edwards signaling reflective beam 330 ft the ec100r is a security beam smoke detector from ge security consisting of an enclosed receiver and transmitter generally installed below the ceiling at about 19 to 24. Ul listed products must comply with nfpa72 ensure clear line of sight between detector and reflector it is recommended at least 0. Read this instruction manual carefully prior to installation. The fireray 5000 motorised reflective, auto aligning infrared optical beam smoke detector can be installed with up to two detector heads per system, thus saving on installation time and costs. The transmitter emits an invisible infrared light beam that is reflected via a prism mounted directly opposite. The fireray 50r 100r series of reflective infrared optical beam smoke detectors are comprised of a single unit incorporating an infrared transmitter and receiver. Line detector using an optical beam fire safety productlistings l ul l ulc l fm l afnor l ceemcandcpd l cfe l vds l activfire l bosec l csfm.